Claims review

FerroFED’s manufacturer reviews what its public texts claim, once per release, against two provisions of Regulation (EU) 2025/327 on the European Health Data Space. This page is the method, the record of each review, and the assessment of the features that could burden access to health data. Every quotation is from the Official Journal text, vendored at docs/specs/eu-ehds/reg-eu-2025-327-en.xhtml. This page is not legal advice.

What the Regulation asks

Art 28 forbids, “in the information sheet, instructions for use or other information accompanying EHR systems, and in the advertising of EHR systems”, any text or sign that may mislead the professional user “with regard to their intended purpose, interoperability and security” by:

  • “(a) ascribing functions and properties to the EHR system which it does not have;”
  • “(b) failing to inform the professional user of likely limitations related to interoperability or security features of the EHR system in relation to its intended purpose;”
  • “(c) suggesting uses for the EHR system other than those stated to form part of the intended purpose in the technical documentation.”

Annex II, point 2.5: “The harmonised software components of an EHR system shall not include features that prohibit, restrict or place an undue burden on authorised access, personal electronic health data sharing or use of personal electronic health data for permitted purposes.” Art 7(1) gives a person the right to have their data transmitted to another healthcare provider “without hindrance from the healthcare provider or from the manufacturers of the systems used by that healthcare provider”.

How a review is done

The review reads every public text: README.md, SUPPORT.md, SECURITY.md, llms.txt and CITATION.cff; every page of this book; the landing page at https://ferrofed.eu; the README and the manifest description of each crate; and the title, description and labels of both container images. Each statement about FerroFED’s intended purpose, interoperability or security is held to three questions, one per point of Art 28:

  1. Does a release ship it, and does a test hold it? A statement that ascribes more is rewritten, (a).
  2. Does it leave out a limitation a professional user would need? The limitation goes on the Limitations list and next to the statement, (b).
  3. Does it suggest a use outside the intended purpose? It is rewritten, (c).

A review runs before every release cut (docs/release.md, Before the tag), and adds a row to the record below. A finding that is not about a claim, such as a broken command, is fixed in the same change.

The record

ReleaseReviewed onTexts readFindingsFixed in
v0.0.102026-10-06see below16, below#674, except finding 16

Findings of 2026-10-06

Read in full: README.md, SUPPORT.md, SECURITY.md, llms.txt, CITATION.cff, the landing page, the book’s introduction, the Evaluate pages written by hand, the self-description section of the client contract, the README and manifest description of every crate, and the image labels. Every other page of the book was searched for absolute and security words (never, always, guarantee, certified, compliant, secure, safe, “never learns”) and each hit read in its paragraph.

Against Art 28(a), a function or property FerroFED lacks:

  1. README.md, the book’s introduction, the landing page and llms.txt said a client “never learns it was federated”. A client reads every member with its status in meta.federation. Now: a client sends an ordinary query with no federation syntax and gets back an ordinary result set whose meta.federation names each node.
  2. README.md and the book’s introduction said no directly identifying identifier “travels to a node”. The rule covers every request the gateway composes; a body the client writes reaches its node byte for byte (§5.4, N22). Now said that way.
  3. The landing page’s card “No identifier reaches a node”, for the same reason. Now “No identifier in what the gateway sends a node”, with the write body named.
  4. The landing page credited mutual TLS to a node to v0.0.8. It shipped in v0.0.9 (#492).
  5. The landing page said the conformance statement “scores every conformance point … against FerroEHR and EHRbase”. Some points are deferred with a recorded reason, and EHRbase is checked for the node profile only.
  6. The landing page’s quickstart sent a query with no access token and started the gateway with no signing key, so it answered 401. It now writes the key and mints the token as the README does.
  7. The README’s quickstart sent the body 5820 in place of the query. It now reads the query from standard input.

Against Art 28(b), a limitation left out:

  1. Nothing listed the limitations a professional user needs before deploying FerroFED. The claims page now carries them: Limitations.
  2. README.md claimed ITS-REST 1.1.0 “on both faces” without saying that the DEMOGRAPHIC area is not federated and an unserved path answers 501. Now said beside the claim.

Stale or wrong statements, which read as claims about the release a user runs:

  1. README.md named v0.0.7 as current and v0.0.8 as unreleased.
  2. llms.txt named v0.0.8 as on main.
  3. The claims page listed v0.0.9 as unreleased and its query console as planned.
  4. The engine’s and the console’s READMEs listed follow-up forwarding and the query console as planned. Both shipped.
  5. The client contract said OPTIONS {base}/ declares no auth.jwks_uri because the gateway publishes no JWK Set. Every federating gateway publishes one and declares it.
  6. CITATION.cff dated v0.0.9 2026-10-04; its tag and its changelog section are of 2026-10-05.

Not fixed here:

  1. The openehr-federation README says version-identity de-duplication “follows in build order”; it shipped in v0.0.6. The text under-claims, so Art 28 is not breached. A change to that README is a change to the packaged crate and moves its version, which is that crate’s own pull request.

No text suggested a use outside the intended purpose, (c).

Annex II, point 2.5

Point 2.5 binds the harmonised software components, which are not built yet (Regulatory status). They are planned on the same query path (#522), so the features of that path that can stop or delay an answer are assessed now, with Art 7(1), which names the manufacturers of the systems a healthcare provider uses. The Annex II checklist that #525 builds takes its reasoning for point 2.5 from this section.

The completeness default

A federated query is all-or-nothing by default: when a member that was asked does not answer, the query fails 504 or 424 with no rows, and meta.federation names every member with its status (§11.4, N37). A client that accepts a partial answer asks for one per request with openEHR-federation-completeness: partial, and gets the rows of the members that answered, with every missing member named (Completeness).

Assessment: no undue burden. The default is the one the Federation Tier specification requires (N37), and it keeps a clinician from reading part of a record as the whole of it, which Annex II, point 1.1, asks of an EHR system (“does not put at risk patient safety”). Access is not withheld: the partial answer is one header away, and both answers name what is missing. Two settings can turn the default into a burden, and the instructions for use say so:

  • [federation] best_effort = false withdraws the partial answer, so one silent member blocks every answer. Keep the default, true.
  • A node’s consent refusal fails the query 424 until its codes are listed in consent_refusal_codes (Consent). List them for every node that refuses on consent.

The budgets

A member’s request has per_node_timeout_ms (10 seconds by default) and the whole fan-out overall_timeout_ms (25 seconds); a client may shorten the wait, never lengthen it (Timeouts). The gateway serves at most max_concurrent_requests at once and answers 503 with Retry-After past it, may rate-limit each caller with 429 and Retry-After, and sends a member at most max_in_flight_per_node requests at once (Overload protection).

Assessment: no undue burden. The budgets bound how long one request or one slow member can hold the gateway, so one caller cannot take access away from the others. Every limit is configurable, the time budget is declared in OPTIONS {base}/, the per-caller rate is off by default and the same for every caller, and a refused request gets a status and a Retry-After that say when to try again. A deployment that sets the limits below what its members need can delay access; the instructions for use give the sizing.

The pre-filter is optional and off by default. It leaves out a member only where the consent service denies the request, which carries out a restriction the person chose (Art 8). When the consent service cannot answer, every candidate is asked and each node checks consent itself (§13.2.1, N27a) (Consent).

Assessment: no undue burden. The pre-filter removes access only where the person restricted it, and its outage never blocks an answer. A deployment in the EU sets [federation.consent] disclose = false, so an exclusion is not shown to the healthcare provider (Withholding consent exclusions).

Art 7(1): transmission without hindrance

FerroFED holds no clinical data of its own: a record stays at the member CDR that holds it. A write goes, as the client sent it, to the member that controls the record, or for a new object to the member the client names (§12.4, N22, N23), and a routed read comes back as the node answered. The gateway adds no fee, no export limit and no format of its own to either. Exporting the gateway’s own state for a replacement product is Annex II, point 2.6, planned with the log access interface (#660).