Cybersecurity risk assessment

This page is the cybersecurity risk assessment Cadasto B.V. keeps for FerroFED under Regulation (EU) 2024/2847, the Cyber Resilience Act (CRA). Art 13(2) has the manufacturer “undertake an assessment of the cybersecurity risks associated with a product with digital elements” and take its outcome into account “during the planning, design, development, production, delivery and maintenance phases”. Art 13(3) says what it holds: “an analysis of cybersecurity risks based on the intended purpose and reasonably foreseeable use, as well as the conditions of use”, whether and how each point of Annex I, Part I, point (2), applies and is implemented, and how Part I, point (1), and the vulnerability handling of Part II are applied. Annex VII, point 3, makes it part of the technical documentation.

The manufacturer’s side of the CRA is the same for every FerroHEALTH product and is in the family book: who the manufacturer is (The manufacturer), what applies from when and how conformity is assessed (The Cyber Resilience Act), and the vulnerability-handling policy (Security). This page is FerroFED’s own product-level assessment.

Every quotation of the CRA is from the Official Journal text, vendored at docs/specs/eu-cra/reg-eu-2024-2847-en.xhtml (http://data.europa.eu/eli/reg/2024/2847/oj), and Art 104 of Regulation (EU) 2025/327 (the EHDS Regulation) is read from docs/specs/eu-ehds/reg-eu-2025-327-en.xhtml. No conformity assessment has been carried out. A row below describes the evidence the repository holds, never conformity. This page is not legal advice.

Date and revision

This assessment was made on 2026-10-15, against the code of FerroFED 0.0.10 and the main branch after it, and last reviewed on 2026-10-16, against FerroFED 0.0.11. It is updated with each release: the version-bump pull request reviews every row against what the release changes and adds a line to Revisions (docs/release.md, Before the tag, step 5). A vulnerability report, a security advisory or a change to the threat model reopens the rows it touches between releases (Art 13(7)). The assessment that applies to a release is this page at that release’s tag.

One assessment, read under two acts

FerroFED is an EHR system under the EHDS Regulation (Classification). EHDS Art 104(1) replaces CRA Art 13(4), so that for a product of CRA Art 32(5a) “the cybersecurity risk assessment may be part of the risk assessment required by those Union legal acts”. This page uses that: it builds on two records that already exist, and copies neither.

  • The threat model names the assets, the trust boundaries, the attacker positions, and per boundary each threat with the setting and the test that answers it. It covers the whole gateway.
  • The clinical safety risk file is the EHDS-side risk assessment of the two harmonised software components, with each hazard rated before and after its control.

This page reads both against Annex I of the CRA and states what neither says on its own: whether each requirement applies, and the justification where it does not.

Scope

  • The product. Each tagged release is one product with digital elements, in the forms on Forms placed on the market: the source at the tag, the ferrofed tarballs, the gateway image and the operator console image. The library crates reach a user only inside those forms, so they are assessed with them.
  • When. Annex I binds the releases placed on the market from 11 December 2027 (Art 71(2), Art 69(2)). The assessment runs now so that a gap is known before that date.
  • Intended purpose. As stated on Regulatory status: a federation gateway used by healthcare providers, through their client applications, to read and write a patient’s openEHR records across the clinical data repositories (CDRs) of a federation. It holds no clinical data of its own.
  • Reasonably foreseeable use and misuse. The misuse the clinical safety file names (Scope): a wrong configuration, a client that ignores meta.federation, a member that breaks the conditions of membership. For security, also: the development profile run near real data, a listener reached without the TLS hop the deployment is meant to supply, and a release run after a newer one is published, which receives no fix (Hardening).
  • Operating environment. Linux on x86_64 or aarch64, as the image or the binary, behind a reverse proxy, with the services it consumes: the member CDRs, the callers’ issuers, the identity services and an Audit Record Repository (The services a gateway consumes).
  • Time in use. Art 13(3) asks the assessment to take into account “the length of time the product is expected to be in use”. Security fixes are published, in new releases, for five years after each release date, and only the newest release is supported (SECURITY.md), set on the expected time in use that The basis of the five years records, and the rows below hold for that period.
  • Assets. The eight assets of the threat model (Assets). The patient identifier and the routing state weigh most: a leak of the first is a privacy breach, and a wrong route sends a request to another patient’s record.

How the risks were analysed

The threat model applies STRIDE per trust boundary (Trust boundaries). The clinical safety file rates severity and occurrence after the method of EN ISO 14971:2019 (Method). The CRA names no method, so no specification governs the method: our own design. This assessment applies no harmonised standard, common specification or European cybersecurity certification scheme (Annex VII, point 5).

Annex I, Part I, point (1)

“Products with digital elements shall be designed, developed and produced in such a way that they ensure an appropriate level of cybersecurity based on the risks.” The level is the one the threat model sets: every threat it names has a control and a test, or is named as a risk the deployment carries, with the control the operator supplies (Risks the deployment carries).

Annex I, Part I, point (2), point by point

PointAppliesHow FerroFED implements itWhere
(a) no known exploitable vulnerabilitiesyescargo deny check reads the RustSec advisory database and fails on any advisory or yanked crate; it is part of the required check on every change to main, from which a release is tagged. Two exceptions in deny.toml are unmaintained compile-time macros of the console with no runtime code. Dependabot proposes updates; fuzz targets run over the untrusted inputs; each binary embeds its dependency list (cargo auditable); the console’s site build runs its CSS and WebAssembly tools only at pinned releases checked against their SHA-256Checks and gates; deny.toml
(b) secure by default, and resetyesprofile defaults to production; the development profile must be set, takes a restart and prints a red notice. There is no unauthenticated mode; the binary listens on loopback; the admin listener is off; a credential or a patient identifier travels only over https; the audit destination must be chosen once a registry is configured. See ResetConfiguration; What must travel encrypted; B8
(c) security updatesyes, automatic installation excepteda security fix ships as a patch release of the newest release, the only one supported, with no feature changes in it; users hear of it from the advisory and the release feed; the gateway names its support end date and says when it has passed. See Automatic security updatesSECURITY.md; Upgrading
(d) protection from unauthorised access, and reporting ityesevery request is authenticated before the façade reads it; scopes per route; the operator surface and the admin write actions need the operator scope; the ADMIN API is refused. Every refusal is logged as caller-refused under ferrofed::securityB1, B5; Client authentication
(e) confidentialityyesin transit: https for every credential and patient identifier outside development, mutual TLS and DPoP where configured, TLS on the listener as an option. At rest: no clinical data is written to disk; secrets are read from files, redacted and zeroised, and a secret the operator console sets is written to a new file of mode 0600 and held in a configuration revision only as its reference; the audit spool is 0700 and is encrypted by the volume, which the deployment suppliesB2, B6; Hardening
(f) integrity, and reporting corruptionsyeseach release is built in an isolated lane with signed provenance, verified with gh attestation verify; the image runs read-only; config check refuses a defective configuration and a refused reload keeps the running one; two members claiming one ehr_id is 409 and an integrity incident, counted and alertedIntegrity incidents; The image
(g) data minimisationyesthe patient identifier is consumed at the gateway and never reaches a node (§5.4, N33); clinical content stays in memory for one request; logs, metrics and spans carry no body, query text, header value or patient identifierWhere the patient identifier stops; Processing inventory
(h) availability, also after an incidentyesa concurrency limit, a per-caller rate, a body limit and a request timeout; per-node and overall budgets; several replicas and a bounded drain on stop; after a restart the routing state is learned again from the next resolutions and answers, and the spool delivers what it holdsOverload protection; Running several replicas; Health probes
(i) minimal impact on other devices and networksyesone federated query is a request to every member, so the gateway caps requests in flight per member, bounds each answer it reads, and reads an issuer’s key set again at most once per auth.jwks_refresh_interval_secondsThe per-member cap; The answer bound; B7
(j) limited attack surfaceyesan ITS-REST path the gateway does not serve answers 501; only the health family, GET {base}/ and the JWK Set are open; the admin listener is off unless set and on loopback unless allowed; the image has no shell; a build can leave out a regional bindingB1; The bindings and their features
(k) exploitation mitigationyesRust with unsafe code forbidden in every crate and overflow checks in the release build; the image runs as a non-root user with every capability dropped; the outbound gate stops a finished request that carries a consumed identifier and fails closedThe container; What the outbound gate reads
(l) recording and monitoring, with an opt-outyes, the opt-out in partevery access to patient data is recorded with the verified caller; IHE transactions are audited over ITI-20; refusals and admin write actions are logged under ferrofed::security; metrics and traces are exported when turned on. See The opt-outThe access log; The audit trail; Metrics
(m) secure removal of data and settings, and secure transferyesthe gateway keeps its configuration, registry, secrets, the stored-query store, the audit spools and, under config.ui = "managed", the configuration revisions; each is a file or a database schema the operator removes. The learned routes are exported for a replacement productWhat the gateway keeps; Exporting the identity state; Decommissioning

Reset to the original state

Point (b) asks for “the possibility to reset the product to its original state”. The binary and the image do not change while they run: the image’s root filesystem is read-only. The gateway’s state is what the operator gives it and what it keeps: the configuration and registry files, the secrets, the stored-query store and the audit spools. The resolution bindings, the ehr_id index and the learned routes are held in memory and lost on a restart (What the gateway keeps). Starting the release with the example configuration it attaches, an empty stored-query store and empty spools returns it to the state it shipped in. Empty a spool only once the dependency report shows audit_repository and audit_feed as up, or its records are lost (Losing a spool).

Automatic security updates

Point (c) asks for automatic security updates “where applicable”, and Annex I, Part II, point (7), asks for automatic distribution “where applicable for security updates”. They do not apply to FerroFED, and the gateway installs no update and asks no server of the manufacturer for one:

  • An upgrade can need a configuration change: a key made mandatory or a value now refused, listed in the release’s upgrade notes, which config check verifies before the new release runs (Before you upgrade).
  • An upgrade can migrate the stored-query store, which an older release then refuses, so the operator backs it up first.
  • The gateway sits on the path of every clinical query of a federation. An update on the manufacturer’s schedule would restart it at a moment no operator chose, and a channel from the manufacturer into the deployment would be a new inbound path.

The operator installs each update, and is told of it by the channels of Hearing of an update and by the gateway itself once the end date of its release has passed.

The opt-out for recording

Point (l) asks for recording “with an opt-out mechanism for the user”. The log level, the metrics surface and the trace export are the operator’s to set, and the metrics and the traces are off by default (Metrics, Tracing). The record of each access to patient data has no opt-out outside the development profile: EHDS Annex II, point 3.2, has the European logging software component “record at least the following information on every access event or group of events”, and the gateway refuses an [audit] destination of off or log outside development once a registry is configured ([audit]). Where the two acts meet, the EHDS requirement decides, and no opt-out is offered for those records.

Annex I, Part II: vulnerability handling

Part II sets the manufacturer’s processes, and the family book’s Security page states them for every product. What is FerroFED’s own:

  • Point (1), the SBOM. Each release attaches a CycloneDX SBOM of the source graph and an SPDX SBOM of the shipped binary per tarball, and attests an SPDX SBOM per platform of each image (The release binaries).
  • Point (2), remediation. Point (2) asks that “where technically feasible, new security updates shall be provided separately from functionality updates”. A security fix ships as a patch release of the newest release, the only one supported, with no feature changes in it (SECURITY.md).
  • Point (3), tests and reviews. The required checks run on every change; the leakage track 10 and the identifier-integrity track 11 run against the gateway (Conformance matrix); CodeQL and the fuzz targets run beside them.
  • Points (4) to (6) and (8). The advisories, the disclosure policy and the reporting address are the family book’s, applied through SECURITY.md.
  • Point (7), secure distribution. Each release is built in a reusable workflow from a cold checkout, signed through Sigstore, and verifiable by digest; a published release cannot be changed (The image).

Residual risk

The risks the gateway cannot close alone, each with the control the deployment supplies or the issue that tracks it, are the threat model’s Risks the deployment carries. The residual risk of the two harmonised components is the clinical safety file’s Overall residual risk. The operator reads both before a deployment goes live, and the instructions for use name the ones a professional user needs to know.

Revisions

RevisionDateReleaseChange
12026-10-150.0.10, and main before 0.0.11first assessment
22026-10-15main before 0.0.11Annex I, Part II, point (2): a security fix ships as its own patch release on each supported line, with no feature changes in it
32026-10-160.0.11every row reviewed against the release: point (a) adds the pinned and checked tools of the console’s site build; point (e) the write-only secrets of configuration revisions; point (m) the revision store among what the gateway keeps. Configuration revisions and the console’s admin actions run on the admin listener behind the operator scope, as point (d) already says, and a configuration or registry refusal names no credential carried in a URL. No point changes whether it applies
42026-10-19main before 0.0.12Annex I, Part II, point (2), and the time in use: only the newest release is supported, and a security fix ships as a patch release of it, with no feature changes in it